Typical project: gas boiler with a wall-mounted water heater and a hydraulic separator

Piping of a Baxi ECO Life 1.24 F system boiler with an 80-litre indirect water heater: a PPR 75 hydraulic separator, a mixing unit and a polypropylene manifold.

  • Baxi ECO Life 1.24 F boiler — a wall-mounted gas heat-only (system) boiler.
  • 80-litre indirect water heater — to the right of the boiler, with its pipes running vertically and in parallel.
  • Hydraulic separator made of PPR 75 pipe — decouples the boiler circuit from the consumer circuit.
  • Mixing unit between the separator and the manifold — keeps the supply temperature by a sensor.
  • Pump on the return line, thermometers on supply and return.
  • PPR manifold — cheap and simple.
  • Drain at the bottom and a safety group at the top of the separator — sludge removal and air venting.

Project description

A typical piping layout of a gas boiler with an indirect water heater, built in the 3D editor pipes.applicode.ru. It suits a house or an apartment where a heat-only boiler heats both the radiators and the domestic hot water. Let us go through the units one by one.

Boiler and indirect water heater

The heat source is a wall-mounted Baxi ECO Life 1.24 F gas boiler. An 80-litre indirect water heater hangs on the wall to its right. The pipes run vertically and parallel to each other: the installation looks neat and the layout is easy to read — you can see at once where each line goes.

Hydraulic separator made of PPR 75

The heating medium is supplied through a hydraulic separator — a vertical 75 mm polypropylene pipe with 32 mm pipes from the boiler and 32 mm pipes to the manifold welded into it. The separator hydraulically decouples the boiler circuit from the consumer circuit: the pumps do not interfere with each other, and the flow through the boiler does not depend on how many radiators are open.

A drain valve at the bottom lets you flush out sludge: the flow slows down in the wide pipe and dirt settles at the bottom. A safety group (relief valve, automatic air vent and pressure gauge) at the top reliably collects air at the highest point and removes it from the system.

Mixing unit and pump

A mixing unit between the separator and the manifold blends cooled return water into the supply and keeps the temperature by a sensor, so consumers get a stable supply temperature regardless of the boiler mode.

The circulation pump is installed on the return line, where the water is cooler — easier on the pump. Thermometers on supply and return make it easy to check the temperature difference.

Polypropylene manifold

The manifold is assembled from PPR fittings. It is cheaper than a factory manifold and is welded with the same tools as the rest of the system — simple and reliable.

Why is it convenient to work with the project in TuboTools?

The 3D view with water flow animation clearly shows how the heating medium passes through the separator, the mixing unit and the manifold — useful for a customer or as a training aid.

You can copy the layout to your account and use it as a basis for your own project.